Models Affected...
All 23/25/27 and 29 cubic foot electronic side-by-side
refrigerator units with plastic liners manufactured in 2001 or later. This
includes all ProfileTM (ArcticaTM and EternaTM )
models.
Consumer Issues...
Consumers have called with reports of freezing in the
Vegetable (middle) pan or the CustomCoolTM (bottom) pan, frozen water
tank or frozen water filter.
Freezing in the pans will lead to the following customer
concerns:
Food freezes in middle pan
Food freezes in bottom pan
A frozen water tank will lead to the following customer
concerns:
Will not dispense water
Water dispenses at a slow rate
Water dispenses intermittently
A frozen water filter will lead to the following customer
concerns:
Will not dispense water
Water dispenses at a slow rate
Water dispenses intermittently
Not making ice
Ice production/dispensation rate too slow
Filter cracked/bust
Filter frozen
Cause of Freezing...
Freezing in the pans, a frozen water tank or a frozen water
filter is caused by excessive airflow from the vents in the tower.
Recommended Repair...
To eliminate these freezing issues, install kit WR49X10045.
Follow the instructions included in the kit.
Please Note: Installation of a new main control board will
not reduce freezing in these areas.

Damper door broken GE arctica:
Affects all 2001 models produced with "M" as the
eight letters in the model i.e.: PSS25SGM with serial date code LA4 , MA4 , RA4
, SA4 , TA4 , VA4 , ZA4 & AD4. Freezing happens when damper door breaks
leaving the unit with no control over the very cold air entering fresh food
compartment from the freezer.
Replace damper door assembly , with new damper door kit WR49X10091.
To verify the damper door is broken , remove the light
shield and rear light bulb from the top of the refrigerator. Enter the factory
diagnostic mode by pushing all four temperature control buttons at the same
time. Perform damper motor test ( FZ 1 , FF 0 ). Press any other button i.e.
Custom cool or filter reset to start damper test cycle. Shine flashlight through
right hand side opening of light assembly to view movement of damper door. To
exit test mode ( FZ 1 , FF 6 ). lf damper door assembly needs to be replaced ,
pull top two shelves out 2 ". Pull rear tower assembly slightly forward
with both hands, move to the left and the right to expose the two screws that
secure the duct assembly , also remove both screws that secure the duct to the
ceiling. Replace with new damper motor assembly WR49X10091.