Reference Model: DMT800
Code | Meaning | Condition | Possible Cause |
tE | Temp Sensor Error | When 0.2V or below, or 4.5V or above is maintained for over 3 seconds | Thermistor terminals not connected. Possible pad thermistor, possible main pcboard |
HE | Heater Error | When the temperature change is 4 degrees C or less within the first 10 minutes after the heating starts | Heater terminal not connected. Possible defect: Main Wire-Harness, Heater, Main pcboard |
1E | High temperature Heating error. | When the temperature of the Thermistor is 80 degrees C or above for more than 3 seconds | Water supply temperature of 80 degrees C or above. Possible defect: Thermistor, Main pcboard |
9E | Low-level water error | 1. When high level sensor is not detected after water supply was done, drain & refill the water. After then, if high level sensor is not detected again, this error is occurred. 2. When low level sensor is detected over 5 seconds during wash operation, this error is occurred. | Water-level sensor terminal is not connected. Possible defect: Assy case sensor, Water Level Sensor, Man pcboard |
PE | Half load function error | When micro s/w is not detected for over 30 seconds after the Distributor motor starts | Distributor motor defect. Micro SW terminal is not connected. Main pcboard defect. |
4E | Water supply error | 1. When the pulse of 100 or less is detected even 73 seconds after the water supply. 2. When flow meter pulse is 5 or less for 13 seconds after the water supply starts. 3. When the water supply does not complete 6 minutes after the water supply starts. | Alien particles within water supply valve. Water supply valve terminal not connected. Possible defect: Main pcboard, Water supply valve , Flow Meter. |
3E | High temperature Water supply error | When 80 degrees C or above is detected during water supply | Water supply temperature is 80 degrees C or above. Possible defect: Thermistor, Main pcboard |
5E | Drain error | When OFF status of Low Level S/W is not detected within 3 minutes during the drain | Alien particles are clogging in drain hose. Drain pump terminal is not connected. Possible defect: Drain pump, Water-level sensor, Main pcboard |
oE | Over-level water error | When overflow detection AD data is 3.5V or below for 3 seconds (When leakage sensor detects 3.5V or below for 1 seconds during water supply) | Alien particles within water supply valve. Case Sensor part breakdown. Possible defect: Flow Meter, Main pcboard, Water supply valve. |
LE | Leakage | High temperature Heating error. | Possible defect: Each hose connection , Sump and Tub assembly, Drain Pump assembly , Main pcboard |
bE | Button error | When the button is pressed continuously for over 30 seconds | Possible defect: Sub board in control panel, Main pcboard. |
dE | Door open warning | When door is open in washing period | Door is not closed properly in test mode only. Possible defect: Door lock switch, Main pcboard |
CE | Communication Error | Functional error. Turn off the dishwasher and try to start it again. If the problem continues, contact an authorized Samsung service center | Functional error. Turn off the dishwasher and try to start it again. If the problem continues, contact an authorized Samsung service center |