Reference Model: WMH53520CS-0
Problem: Microwave overheating after 2 or 3 minutes of running.
Diagnosis: The thermal cut off mounted to the magnetron may be breaking the circuit. If this is the case, one of the following issues may be the cause for malfunction:
- The magnetron cooling fan is running slowly or not at all
- The exhaust vent or magnetron cooling fan opening is blocked
- The magnetron is running hot and needs replacement
- The magnetron thermal cut off is faulty
Item Number W10818686
Magnetron
Item Number W10598693
High limit safety thermostat
Item Number W10727360
Door switch, three terminal
Item Number W11707984
Microwave line fuse 20A 250V
Related Links: