F1: Temperature runaway.
Membrane switch shorted. Alarm is continuous. If cancel key is pressed alarm will stop. If
fault still present alarm will repeat. If membrane switch is disconnected the alarm will
only sound for 30 seconds and stop. Correction: Test membrane switch and sensor. If
ok, replace control.
F3: Open or shorted sensor. The cancel key resets
the control and stops the alarm. If fault is still present it will reactivate the alarm
when the cook mode is chosen. Correction: Check sensor and wiring for shorted or open
circuit.
F9: Door lock error. Check the status of the door
lock switches.
| Maytag Gemini fault codes. |
|
|
|
| Fault code |
Suspect area |
Fault code |
Suspect area |
| F0 - 0 |
None |
F1 - 9 |
Slave |
| F1 - 1 |
Runaway cook upper oven |
F1 - A |
Latch switch upper |
| F1 - 2 |
Runaway cook lower oven |
F1 - B |
Latch switch lower |
| F1 - 3 |
Runaway clean upper oven |
F1 - C |
Door switch upper |
| F1 - 4 |
Runaway clean lower oven |
F1 - D |
Door switch lower |
| F1 - 5 |
Keypad cancel upper |
F1 - E |
EEPROM, Control |
| F1 - 6 |
Keypad cancel lower |
F1 - F |
Jumper, Control |
| F1 - 7 |
Keypad disconnected |
F1 - H |
EEPROM, Read, control |
| F1 - 8 |
Keypad shorted |
F1 - L |
Sensor, Track, Control |
| F3 - 1 |
Sensor upper oven |
F3 - 2 |
Sensor lower oven |
| F9 - 1 |
Latch lock upper |
F9 - 2 |
Latch unlock upper |
| F9 - 3 |
Latch lock lower |
F9 - 4 |
Latch lock lower |
| F9 - 5 |
Latch unlock lower |
F9 - 6 |
Latch both lower |
| Maytag's Accellis 2X Range fault
codes |
|
|
|
| Fault code |
Suspect area |
Fault code |
Suspect area |
| F0 - 0 |
None |
F1 - 9 |
Control not calibrated |
| F1 - 1 |
Oven temp over 650ºF |
F1 - A |
Latch switch |
| F1 - 2 |
Oven temp over 950ºF |
F1 - C |
Door switch |
| F1 - 3 |
Shorted key in
membrane
switch |
F1 - E |
Control not calibrated |
| F1 - 4 |
Membrane disconnected |
F1 - F |
Jumper wire disconnected |
| F1 - 5 |
Cancel key not responding |
F1 - H |
EEPROM, Read, Control |
| F1 - 7 |
Slave microprocessor not
responding |
F1 - N |
VCC, Control |
| F1 - 8 |
EEPROM error |
F2 - 1 |
Door state input circuitry failure |
| F3 - 1 |
Sensor is shorted or open |
F9 - 1 |
Door lock will not lock |
| |
Do you think a repair
manual would help you?


Analog
Volt/Ohm Meter - Basic meter for measuring most appliance voltages, resistance,
and continuity. It features a fuse protected Ohms circuit.
Includes test leads, AA battery and instructions.
|