**Always check local electrical codes and the use/care manual for your appliance.**
GFI outlets and your appliances.
Gas range - 110 -120 volt, 60 hertz, properly grounded branch circuit protected by a 15/20 amp circuit breaker or fuse. Must be properly grounded and polarized. #14 gauge house wire minimum for 15 amp protection, #12 gauge is a must for 20 amp protection.
A/w - 110 - 120 volt, 60 hertz 15/20 amp circuit breaker or fused electrical supply line. Power cord must be connected to a properly grounded and polarized outlet. Because of water conditions found in a laundry room, a GFI ( ground fault interrupter ) outlet might also be considered. #14 gauge house wire minimum for 15 amp protection, #12 gauge is a must for 20 amp protection.
Microwave - 110 - 120 volt, 60 hertz, properly grounded circuit protected by a 15/20 amp circuit breaker or fuse. #14 gauge house wire minimum for 15 amp protection, #12 gauge is a must for 20 amp protection. A separate (dedicated ) circuit serving this appliance is recommended.
Dishwasher - 110 - 120 volt, 60 hertz, properly grounded circuit protected by a minimum 15 amp breaker or fuse ( d/w without temp boost ) to a maximum of 20 amp breaker or fuse ( d/w with temp boost ) #14 gauge house wire minimum for 15 amp protection, #12 gauge is a must for 20 amp protection. A separate (dedicated ) circuit serving this appliance is recommended.
Refrigerator - 110 - 120 volt, 60 hertz, properly grounded circuit protected by a 15 amp circuit breaker or fuse. #14 gauge house wire minimum, #12 is preferred. A separate (dedicated ) circuit serving this appliance is recommended.
Gas dryer - 110 - 120 volt, 60 hertz, properly grounded circuit protected by a 15 amp circuit breaker or fuse. #14 gauge house wire minimum, #12 is preferred.
Electric dryer - 220 - 240 volt, 60 hertz, properly grounded circuit with 30 amp breaker or fuse protection. #10 gauge wire is preferred.
Electric Range - 220 - 240 volt, 60 hertz, properly grounded circuit with 40 amp breaker or fuse protection with #8 gauge wire. With a 50 amp breaker, # 6 gauge wire is required.
**Always check local electrical codes and the use/care manual for your appliance.**
Wiring help for the 4 prone receptacle